Contact Info
TEL: 028-84193018
FAX: 028-84193058
Add: 515,Building 1,NO39,Jiancai road,Chenghua district,Chengdu,Sichuan,China
Mammography X-ray System

YSD9800D Rotated Mammography System X-ray Machine

Item No.: YSD372
$0.00
INQUIRY
Description
YSD9800D High Frequency Mammography Unit


Application:

Mammography Unit is a X-ray apparatus involving in various advanced technologies, specially designed for the diagnosis of mammary gland diseases. It is sensitive to mammary gland lump, calcification, protuberance and carcinogensis and first-choice apparatus for the image examination of mammary diseases in medical institutes.
 


Main Parameters

1.    X-ray Generator

       Complete solid-state high-frequency high-voltage generator.
       Generator Type: High Frequency Inverter 80kHz
       Input Power: Single phase 220VAC, 50/60Hz
       Radiographic Ratings: Large Focal Point 20-35kV/10-510mAs
                                           Small Focal Point 20-35kV/10-100mAs
       Power Rating: 6.2kW
 

2.    Radiographic Stand

       C-ARM: Vertical Movement: 590mm
       Center of electric rotating C-arm, automatic return function by one key
       Automatically released after the exposure pressure settings display
       Compression flexible stepless speed.
       Max. pressure: 200N
       Max. travel: 150mm
       Rotations Deg:+90°~-90°
       SID: 650mm
 
3.    Cassette Image Receptor

       18*24cm (24cm*30cm optional)
       Bucky Device: 18*24cm Bucky drive mechanism,(24cm*30cm optional)
       Grid Ratio: 5:1, 30 Line/cm
 
4.    Line Voltage

       220Vac@25A, Single phase
 
5.    Weight and Size:

       240kg(Gross weight: 340kg)
       L*W×H: 940mm*560mm*2000mm
 
 

Upgrading:

Above introduction for YSD9800D is an anal og mammography, actually, it can be upgraded into a DR system. Here is the main parameters for digital mammography.
 

Main Parameters for Full Digital Mammography System:

 
Name Parameters
Specialized Digital Flat Panel Detector for Mammography Detector, Power Box, Date Line, Capture Card, etc
Effective Coverage of Detector 23*15cm, 29*23cm
Pixel Matrix 3072*1944, 3888*3072
Limit of Spatial Resolution 6.0Lp/mm
DQE Value 70%
Dynamic Range 14bit digital output
Pixel Size 75um
High Voltage Synchronizer BNC
Output Camera Link or Ethernet
Working Condition 10-40ºC
Storage Environment -10-50ºC
Bucky Housing and Movement Device
Size 370*275*125cm
Stepless Speed Regulating Range 0-6cm/s
Movement Range 0.5-2cm
Grid
Size 24*30cm
Grid Ratio 3.5:1
Focal Distance 65cm
Software
Workstation Standard Detector Image Acquisition Workstation
CPU≥Intel Duo Core 2.60GHz
Hardware≥250G
Memory≥2G
Display Card≥512MB
19'' High Brightness High Contrast LCD, 1280*1024 Pixel Resolution
Network Interface Worklist
DICOM3.0 Transmission
100/1000 Gigabit Ethernet
 
TOP